Start

Gallery

Download DWG files

About us

Sealant

Contact

Connectors for steel sheet pile walls

Connectors for pipe pile steel walls

Pipe spacing ~2.48" (63 mm)

Steel thickness 0.47" (12 mm)

Also suitable for Ball + Socket sheet piles

Pipe spacing ~2.5" (64 mm)

For pipe pile steel walls using DTH driving method

Steel thickness 0.47" (12 mm)

Steel thickness 0.39 - 0.47" (10 - 12 mm)

Pipe spacing ~3" (75 mm)

Steel thickness 0.47" (12 mm)

Also suitable for Ball + Socket sheet piles

Steel thickness 0.47" (12 mm)

Pipe spacing ~4" (100 mm)

Steel thickness 0.39" (10 mm)

Pipe spacing ~7.1" (180 mm)

Steel thickness 0.39" (10 mm)

Steel thickness 0.47" (12 mm)

Steel thickness 0.47" (12 mm)

Also suitable for Ball + Socket sheet piles

Steel thickness 0.47" (12 mm)

Also suitable for Ball + Socket sheet piles

Steel thickness 0.47" (12 mm)

Steel thickness 0.63" (16 mm)

Pipe spacing ~9.055" (230 mm)

Steel thickness 0.47" (12 mm)

Also suitable for Ball + Socket sheet piles

Pipe spacing ~9.8" (248 mm)

Steel thickness 0.47" (12 mm)

Pipe spacing ~10" (250 mm)

Steel thickness 0.47" (12 mm), clutch bars with high deformation capacity

Pipe spacing  ~11.8" (300 mm)

Steel thickness 0.47" (12 mm), clutch bar with very high tensile strength

Steel thickness 0.63" (16 mm)

MF63 (M35 + F28)

Steel grade:  S355

Steel thickness:  0.47"

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M35:  3.2 lbs/ft

Weight F28:  7.19 lbs/ft

Max. tensile strength: 14.57 kips/in (FEM)

PDF Data sheet

DWG M35

DWG F28

Request this connector

MF64 (M22 + F40)

Steel grade:  S355

Steel thickness:  0.47"

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M22:  2.28 lbs/ft

Weight F40:  9.6 lbs/ft

Max. tensile strength: 19.52 kips/in

PDF Test report

PDF Data sheet

DWG M22

DWG F40

Request this connector

MF64-IC (M22 + F40-IC)

Steel grade:  S355

Steel thickness:  0.39" - 0.47"

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M22:  2.38 lbs/ft

Weight F40-IC:  9.1 lbs/ft

Max. tensile strength:  18.08 kips/in

PDF Data sheet

DWG M22

DWG F40-IC

Request this connector

MF75 (M35 + F40)

Steel grade:  S355

Steel thickness:  0.47“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M35: 3.198 lbs/ft

Weight F40:  9.595 lbs/ft

Max. tensile strength:  19.52 kips/in

PDF Test report

PDF Data sheet

DWG M35

DWG F40

Request this connector

MF75-IC (M35 + F40-IC)

Steel grade:  S355

Steel thickness:  0.39 / 0.47"

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M35:  3.2 lbs/ft

Weight F40-IC:  9.1 lbs/ft

Max. tensile strength:  18.08 kips/in

PDF Data sheet

DWG M35

DWG F40-IC

Request this connector

LPB100-10

Steel grade:  S355

Steel thickness:  0.39“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight:  6.63 lbs/ft

Max. tensile strength:  5.6 kips/in

PDF Test report

PDF Data sheet

DWG

Request this connector

LPB180-10

Steel grades:  S430

Steel thickness:  0.39“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight:  8.7 lbs/ft

Max. tensile strength:  5.86 kips/in

PDF Test report

PDF Data sheet

DWG

Request this connector

LPB180-12

Steel grade: S355

Steel thickness: 0.47“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight: 9.74 lbs/ft

Max. tensile strength: 8.58 kips/in

PDF Test report

PDF Data sheet

DWG

Request this connector

MF180 (M90 + F90)

Steel grade:  S355

Steel thickness:  0.47“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M90:  6.56 lbs/ft

Weight F90:  12.38 lbs/ft

Max. tensile strength:  12.15 kips/in

PDF Data sheet

DWG M90

DWG F90

Request this connector

MF180 (M140 + F40)

Steel grade: S355

Steel thickness: 0.47“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M140: 9.88 lbs/ft

Weight F40: 9.6 lbs/ft

Max. tensile strength: 19.52 kips/in

PDF Data sheet

DWG M140

DWG F40

Request this connector

FD180

Steel grade: S355

Steel thickness: 0.47"

Lengths: 38.7 ft, 59 ft

Weight: 11.71 lbs/ft

Max. tensile strength: 33.37 kips/in

PDF Data sheet

DWG FD180-12

Request this connector

LPB180-16

Steel grade: S355

Steel thickness: 0.63“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight: 15.05 lbs/ft

Max. tensile strength:

see LPB300-16

PDF Data sheet

DWG

Request this connector

MF230 (M140 + F90)

Steel grade: S355

Steel thickness: 0.47“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight M140: 9.92 lbs/ft

Weight F90:  12.38 lbs/ft

Max. tensile strength: 12.15 kips/in

PDF Data sheet

DWG M140

DWG F90

Request this connector

LPB248-12

Steel grade: S355

Steel thickness: 0.47“

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight: 12.27 lbs/ft

Max. tensile strength: 8.57 kips/in

PDF Data sheet

DWG

Request this connector

LZ250-12-A, LZ250-12-B

Steel grade: S355

Steel thickness: 0.47"

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled)

Weight: 13.1 lbs/ft each

Deformation path: ±2"

Max. tensile strength: 6.85 kips/in

Pressure load: 4.57 kips/in

PDF FEM Simulation

PDF Data sheet

DWG LZ250-12-A

DWG LZ250-12-B

Request this connector

FD300-12

Steel grade: S355J2

Steel thickness: 0.47"

Length: 45.27 ft

Weight: 14.38 lbs/ft

Max. tensile strength: 33.37 kips/in

PDF Test report

PDF Data sheet

DWG

Request this connector

LPB300-16

Steel grades: S355J2, S430GP

Steel thickness: 0.63"

Standard lengths:

26.25 ft (hot rolled)

38.7 ft (hot rolled))

Weight: 19.92 lbs/ft

Max. tensile strength: 10.43 kips/in

PDF Test report

PDF Data sheet

DWG

Request this connector

Test report / download

Tensile and twist out tests

Connectors

overview 2022

Technical data / disclaimer

SteelWall connectors generally comply with the European standards and are manufactured by certified steel processing companies.

All figures are approximate and may vary. Bar twists are possible up to 0.025"/ft (2 mm per meter). Tolerance of steel thickness ±0.04" (±1 mm). Length tolerance up to ±7.9" (±200 mm). Degree details refer to the connector bar axes. Welding base of LPB and FD clutches can be straight or beveled. We reserve the right to make technical changes. We refer to DIN EN 12063. Please check the sheet pile interlocks with a physical sample section of the desired connector for compatibility.

 

2022-July-27, Copyright by SteelWall ISH GmbH. Connectors designed by Richard Heindl.

TOLL FREE: 1(888) 309 2250

US sales line 8:30 am to 4:30 pm (Central Time)

E-Mail: info@steelwallus.com

Imprint

General terms and conditions

Privacy