Connectors for sheet pile wall structures
Corner connectors, T connectors, cross connectors, weld-on connectors
Connectors for pipe pile combined steel walls
For Larssen Z sheet piles
For Larssen Z sheet piles
For Larssen Z sheet piles
For Larssen Z sheet piles
For Larssen Z sheet piles
For Ball + Socket sheet piles
For Ball + Socket sheet piles
For Ball + Socket sheet piles
For Ball + Socket sheet piles
For Ball + Socket sheet piles
For midsize cold-formed sheet piles (Z-type)
L8
Steel grade: S355
Steel thickness: 0.375“
Standard length: 38.7 ft (hot rolled)
Weight: 5.69 lbs/ft
PDF Data sheet
DWG
Request this connector
LV22
Steel grade: S355
Steel thickness: 0.32“
Standard length: 38.7 ft (hot rolled)
Weight: 5.39 lbs/ft
PDF Data sheet
DWG
Request this connector
LPB100-9A
Steel grade: S355
Steel thickness: 0.35"
Standard lengths:
26.25 ft (hot rolled),
38.7 ft (hot rolled)
Weight: 6.08 lbs/ft
Max. tensile strength: 5.21 kips/in
PDF Data sheet
DWG
Request this connector
LPB100-10
Steel grade: S355
Steel thickness: 0.39"
Standard lengths:
26.25 ft (hot rolled),
38.7 ft (hot rolled)
Weight: 6.63 lbs/ft
Max. tensile strength: 5.60 kips/in
PDF Data sheet
DWG
Request this connector
Gallery LPB100-10
LPB180-10
Steel grade: S430
Steel thickness: 0.39“
Standard lengths:
26.25 ft (hot rolled)
38.7 ft (hot rolled)
Weight: 8.7 lbs/ft
Max. tensile strength: 5.86 kips/in
PDF Data sheet
DWG
Request this connector
MF50 (M22 + F28)
Steel grade: S355
Steel thickness: 0.47"
Standard lengths:
26.25 ft (hot rolled)
38.7 ft (hot rolled)
Weight M22: 2.3 lbs/ft
Weight F28: 7.19 lbs/ft
Max. tensile strength:
14.57 kips/in (FEM)
PDF Data sheet
DWG M22
DWG F28
Request this connector
MF75 (M35 + F40)
Steel grade: S355
Steel thickness: 0.47"
Standard lengths:
26.25 ft (hot rolled)
38.7 ft (hot rolled)
Weight M35: 3.2 lbs/ft
Weight F40: 9.6 lbs/ft
Max. tensile strength: 19.52 kips/in
PDF Data sheet
DWG M35
DWG F40
Request this connector
MF100 (M60 + F40)
Steel grade: S355
Steel thickness: 0.47"
Standard lengths:
26.25 ft (hot rolled)
38.7 ft (hot rolled)
Weight M60: 4.64 lbs/ft
Weight F40: 9.6 lbs/ft
Max. tensile strength: 19.52 kips/in
PDF Data sheet
DWG M60
DWG F40
Request this connector
MF180 (M90 + F90)
Steel grade: S355
Steel thickness: 0.47“
Standard lengths:
26.25 ft (hot rolled)
38.7 ft (hot rolled)
Weight M90: 6.56 lbs/ft
Weight F90: 12.36 lbs/ft
Max. tensile strength: 12.15 kips/in
PDF Data sheet
DWG M90
DWG F90
Request this connector
MDF310 (M140 + DF)
Steel grade M140: S355
Steel grade DF: S430
Steel thickness: 0.47“
Standard lengths:
26.25 ft, 38.7 ft
Weight M140: 9.88 lbs/ft
Weight DF: 9.82 lbs/ft
Max. tensile strength:
18.7 kips/in (FEM)
PDF Data sheet
DWG M140
DWG DF
Request this connector
CF-Junction
Steel grade: S355
Steel thickness: 0.32"
Standard length: 38.7 ft (cold rolled)
Weight: 6 lbs/ft
PDF Data sheet
DWG
Request this connector
Technical data / disclaimer
SteelWall connectors generally comply with the European standards and are manufactured by certified steel processing companies.
All figures are approximate and may vary. Bar twists are possible up to 0.025"/ft (2 mm per meter). Tolerance of steel thickness ±0.04" (±1 mm). Length tolerance up to ±7.9" (±200 mm). Degree details refer to the connector bar axes. Welding base of LPB and FD clutches can be straight or beveled. We reserve the right to make technical changes. We refer to DIN EN 12063. Please check the sheet pile interlocks with a physical sample section of the desired connector for compatibility.
2022-May-15, Copyright by SteelWall ISH GmbH. Connectors designed by Richard Heindl.
TOLL FREE: 1(888) 309 2250
US sales line 8:30 am to 4:30 pm (Central Time)
E-Mail: info@steelwallus.com