L8
Steel grade: S355J2
Steel thickness: 0.375“
Standard length: 38.7 ft
Weight: 5.69 lbs/ft
PDF Data sheet
DWG
Request this connector
LV22
Steel grade: S355J2
Steel thickness: 0.32“
Standard length: 38.7 ft
Weight: 5.39 lbs/ft
PDF Data sheet
DWG
Request this connector
LPB100-9A
Steel grade: S355J2
Steel thickness: 0.35“
Standard lengths:
26.25 ft, 38.7 ft
Weight: 6.08 lbs/ft
Max. tensile strength: 5.2 kips/inch
PDF Data sheet
DWG
Request this connector
LPB180-10
Steel grades: S355J2, S430GP
Steel thickness: 0.39“
Standard lengths: 26.25 ft, 38.7 ft
Weight: 8.628 lbs/ft
PDF Data sheet
DWG
Request this connector
MF63
Steel grade: S355J2
Steel thickness: 0.47“
Standard lengths:
26.25 ft, 38.7 ft
Weight M35: 3.2 lbs/ft
Weight F28: 7.19 lbs/ft
Max. tensile strength:
14.57 kips/in (FEM)
PDF Data sheet
DWG M35
DWG F28
Request this connector
MF75
Steel grade: S355J2
Steel thickness: 0.47“
Standard lengths: 26.25 ft, 38.7 ft
Weight M35: 3.2 lbs/ft
Weight F40: 9.595 lbs/ft
Max. tensile strength: 19.52 kips/in
PDF Test report
PDF Data sheet
DWG M35
DWG F40
Request this connector
MF100
Steel grade: S355J2
Steel thickness: 0.47"
Standard lengths: 26.25 ft, 38.7 ft
Weight M60: 4.64 lbs/ft
Weight F40: 9.595 lbs/ft
Max. tensile strength: 19.52 kips/in
PDF Test report
PDF Data sheet
DWG M60
DWG F40
Request this connector
MF130
Steel grade: S355J2
Steel thickness: 12 mm
Standard lengths: 26.25 ft, 38.7 ft
Weight M90: 6.56 lbs/ft
Weight F40: 9.595 lbs/ft
Max. tensile strength: 18.27 kips/in
(FEM)
PDF FEM Simulation
PDF Data sheet
DWG M90
DWG F40
Request this connector
MF180b
Steel grade: S355J2
Steel thickness: 0.47“
Standard lengths: 26.25 ft, 38.7 ft
Weight M90: 6.56 lbs/ft
Weight F90: 12.38 lbs/ft
Max. tensile strength: 12.15 kips/in
PDF Data sheet
DWG M90
DWG F90
Request this connector
MDF310
Steel grade M140: S355J2
Steel grade DF: S430GP
Steel thickness: 0.47"
Standard lengths: 26.25 ft, 38.7 ft
Weight M140: 9.92 lbs/ft
Weight DF: 9.82 lbs/ft
Max. tensile strength:
18.677 kips/inch (FEM)
PDF Data sheet
PDF FEM Simulation
DWG M140
DWG DF
Request this connector
CF-Junction
Steel grade: S355J2
Steel thickness: 0.32"
Standard length: 38.7 ft
Weight: 6 lbs/ft
PDF Data sheet
DWG
Request this connector
Technical data / disclaimer
SteelWall connectors generally comply with the European standards and are manufactured by certified steel processing companies.
All figures are approximate and may vary. Bar twists are possible up to 0.025"/ft (2 mm per meter). Tolerance of steel thickness ±0.04" (±1 mm). Length tolerance up to ±7.9" (±200 mm). Degree details refer to the connector bar axes. Welding base of LPB and FD clutches can be straight or beveled. We reserve the right to make technical changes. We refer to DIN EN 12063. Please check the sheet pile interlocks with a physical sample section of the desired connector for compatibility.